Fundus camera
Model:RET- 3100
Feature
*One touch images acquisition
*Fast and accurate autofocus
*Non-mydriatic and autoexposure
* photography fundus and Auto fluorescence (FAF)
Smart operation automatic easy and fast
10.1 inch TFT touch screen
Simple as one , two ,three
One:Enter patient information
Two:Choose the eye (OD or OS),and move the pupil between two line marks
Three:Click"Take Picture"
The image will be ready in seconds
Dual-camera system-eyes of the device
Dual-camera system is like eyes of the device.It searches and locates the pupil for fast andaccurate autofocus.
Soft lighting -advanced optical technology
Soft lighting reduces the constriction of pupil caused by the illumination.Satisfactory images can beobtained even in two consecutive exposures.
Non-mydriatic design-Minimum pupil size of 3.3mm
135°wide field 9 position mosaic device
Mosaic Function can generate the fundus images up to 135° field of view form 9 images of 50° field width each .More fixation points are distributed between 9 internal fixations shown.
Quality components -Step motor
High quality step motors reduce nosie effectively and create a quiet environment for the patients and operators.
Multifunctional software system
Specification
Image acquisition system | |
Acuisition modes | Non-mydriatic/mydriatic photography anterior segment photography fundus ,fluorescence angiography (FFA optional). Auto fluorescence (FAF optional) |
Field of view | 50° |
Minimum pupil size | ≥3.3mm |
Focus modes | Auto /manual |
Operation | Auto |
Image acquisition time | Within 10 seconds |
Image resolution | 18 megapixels |
Working distance | 35mm |
Diopter COMPENSATION | ±25D |
Fixation | External fixation/internal fixation |
DICOM3.0 | YES |
Dimensions | 380mm (L)x 550mm(W)X475mm(H) |
Weight | 26.5kg |
Power supply | 100-240V 50/60Hz |
Note:specifications and design are subject to change without notice. |
Fundus camera
Model:RET- 3100
Feature
*One touch images acquisition
*Fast and accurate autofocus
*Non-mydriatic and autoexposure
* photography fundus and Auto fluorescence (FAF)
Smart operation automatic easy and fast
10.1 inch TFT touch screen
Simple as one , two ,three
One:Enter patient information
Two:Choose the eye (OD or OS),and move the pupil between two line marks
Three:Click"Take Picture"
The image will be ready in seconds
Dual-camera system-eyes of the device
Dual-camera system is like eyes of the device.It searches and locates the pupil for fast andaccurate autofocus.
Soft lighting -advanced optical technology
Soft lighting reduces the constriction of pupil caused by the illumination.Satisfactory images can beobtained even in two consecutive exposures.
Non-mydriatic design-Minimum pupil size of 3.3mm
135°wide field 9 position mosaic device
Mosaic Function can generate the fundus images up to 135° field of view form 9 images of 50° field width each .More fixation points are distributed between 9 internal fixations shown.
Quality components -Step motor
High quality step motors reduce nosie effectively and create a quiet environment for the patients and operators.
Multifunctional software system
Specification
Image acquisition system | |
Acuisition modes | Non-mydriatic/mydriatic photography anterior segment photography fundus ,fluorescence angiography (FFA optional). Auto fluorescence (FAF optional) |
Field of view | 50° |
Minimum pupil size | ≥3.3mm |
Focus modes | Auto /manual |
Operation | Auto |
Image acquisition time | Within 10 seconds |
Image resolution | 18 megapixels |
Working distance | 35mm |
Diopter COMPENSATION | ±25D |
Fixation | External fixation/internal fixation |
DICOM3.0 | YES |
Dimensions | 380mm (L)x 550mm(W)X475mm(H) |
Weight | 26.5kg |
Power supply | 100-240V 50/60Hz |
Note:specifications and design are subject to change without notice. |
NO.18 South of Xiangqiao Road of Nanjing ,China
0086-13675174098
0086-25-58575880
helen@redsunoptical.com
redsunoptical