Portable auto refractometer
HAR-800

The HAR-800 vision screener can check the refractive error precisely for different groups of people using the ultrasonic ranging, cross line, flashing light and sound technology and then to find out the probably potential refractive problems.

The HAR-800 vision screener has so many merits, such as portable, fast and accurate testing, non-contact and non-injury to your eyes. It is fit for the refractive screening of huge population since that 5 second is enough for both eyes test. We all know that the refractive status is very important for children just because that if doctor can not find the long-lasting refractive error and cure it properly, children would become amblyopia sadly someday or lose the best chance to treat the lazy eye and finally become the permanent amblyopia. The special model for children testing is the best way for child screening. So it is not only for the adult, but also for the infants and handicapped patients.

HAR-800 vision screener-, the optimal weapon for doctor to master the refractive status of patients.
Main feature.
1. Measure range: SPH-8.00~+6.00, CYL+/-3.00D
2. Mode of measure: Adult, children, myopia mode.
3. Memory: 120 groups of eyes data.
4. Ultrasonic ranging: Automatic monitoring the testing distance(35cm)by the changing sound and cross line color.
5. Battery life: 11.1V polymer lithium battery. Hand-hold unit operates for six hours of continuous testing.
6. Low power tip: Prompt 15 minutes left.
7. Thermal printer: Available battery operated printer enables you to get printouts anywhere any time
8. Can connect to computer, easy to upgrade the software or transfer the data to electric documents.
9. Weight: Weight almost two pounds(1KG)

Product Benefits.

Non-conact and non-invasive The light power is safe for eyes, the working distance of the instrument is 35cm (14inches)
Low cooperation need It do not need too much cooperation of children, it is suitable for infants and disabled individuals.
Automatic operation by one key Complete the automatic diction of two eyes, just need one key operation .A speedy and intelligent design.
Easy to carry Small and lightweight body and printer , easy to carry . It is suitable for outdoor screening.
Accurate result The advanced optical detection principle provides an accurate result:including myopia , hyperopia, astigmatism, axial and anisometropia.
Comprehensive detection modes In fant mode is specially designed for the babies' refraction characteristic. Myopia mode is specially designed for common myopia people and high myopia people (HAR-880 only).
Adult mode is suitable for all adults.
Dual mode distance hint Through ultrasonic measurement of distance , it adopts sound and visual color light prompt the distance.
High performance battery Short charging time and can use for a long time
Large storage capacity 420 data storage
Ultrasonic distance measurement Automatic monitoring the detection distance through audible and visual hint
Aiming The cross-shape is luminous and easy for aiming
Printer Thermal printer by infrared connection
Weight 0.9KG

MODEL: HAR-800 MODEL: HAR-880
WORKING DISTANCE Adult/enfant mode: 335 ± 10mm Adult/enfant mode: 335± 10mm,
myopia mode: 268±10mm
DISTANCE DETECTION Automatic, with audible and visual cues Automatic, with audible and visual cues
DATA ACQUISITION TIME 2s/eye 2s/eye
RELIABILITY MEASURE Indicates number of and variation among measurements for the given eye Indicates number of and variation among measurements for the given eye
BATTERY VOLTAGE d.c.11.1V d.c.11.1V
BATTERY LIFE More than 6 hours of continuous usage More than 6 hours of continuous usage
LOW-BATTERY WARNING: Indicates 15 minutes usage remains Indicates 15 minutes usage remains
WAVELENGTH 850 ± 20nm 850 ± 20nm
OUTPUT OF THE LASER RADIATION 150~200µW 150~200µW
DETECTION MODES Adult Mode, enfant mode Adult Mode, enfant mode, myopia mode
SPHERE RANGE +8.0 to -6.0 Diopters +8.0 to -9.0 Diopters
SPHERE TOLERENCE ± 0.5 Diopters ± 0.5 Diopters
CYLINDER RANGE +3 Diopters +3 Diopters
CYLINDER TOLERENCE ± 0.5 Diopters ± 0.5 Diopters
AXIS OF ASTIGMATISM RANGE 1° ~ 180° 1° ~ 180°
AXIS OF ASTIGMATISM TOLERENCE 0.25D~1.00D : ± 10° 0.25D~1.00D : ± 10°

1.25D~3.00D : ± 5° 1.25D~3.00D : ± 5°


Ophthalmic Equipment, Portable Auto Refractometer (HAR-800/880)Ophthalmic Equipment, Portable Auto Refractometer (HAR-800/880)

Previous: 
Next: 

Subscribe

Be the first to know about our latest products.
Contact

Product

Quick link

Call us

 NO.18 South of Xiangqiao Road of Nanjing ,China
 0086-13675174098
  0086-25-58575880
 helen@redsunoptical.com
 redsunoptical
 0086-13675174098

Copyright  Nanjing Redsun Optical Co., Ltd. All rights reserved. 
Supported by Leadong / Site Map